{"CALC_WATER":{"lang":"en","text":{"next.plan":"✨ Plan the whole house","next.sub":"Opens the «my house» wizard with what you have entered.","rate.calc":"Rate this calculator","rate.article":"Rate this article","rate.star":"{n} of 5","rate.thanks":"Thank you!","rate.comment":"What could be better? (optional)","rate.send":"Send","rate.sent":"Thank you - we will read it.","wt.stage.mech":"Sediment filter 80–150 µm + raw-water tap","wt.stage.h2s":"Hydrogen sulphide removal","wt.stage.iron":"Iron removal","wt.stage.carbon":"Carbon filter","wt.stage.complex":"Combined filter (iron + hardness)","wt.stage.softener":"Water softener with blending valve","wt.stage.ro_poe":"Whole-house reverse osmosis + remineralisation","wt.stage.ro_pou":"Under-sink reverse osmosis with mineraliser","wt.stage.uv":"UV disinfection ≥40 mJ/cm² with sensor + 5 µm filter","wt.media.birm":"catalytic media (Birm type)","wt.media.greensand":"manganese greensand with permanganate","wt.media.mno2":"catalytic manganese-dioxide media (pyrolusite type)","wt.media.catalytic-carbon":"catalytic carbon","wt.media.oxidant-dosing":"oxidant dosing + contact tank + filter","wt.media.carbon":"activated carbon","wt.media.oxidizing":"oxidising filter or aeration","wt.media.oxidation":"chemical oxidation + filter","wt.media.chlorination":"chlorine or permanganate + filter","wt.media.complex":"combined media","wt.media.ion-exchange":"ion-exchange resin","wt.media.ro-poe":"whole-house membrane","wt.media.ro-pou":"under-sink membrane","wt.media.uv":"UV lamp","wt.why.always":"always on a well supply (DIN 1988-200); raw-water tap for later tests","wt.why.h2s-level":"hydrogen sulphide {v} mg/l","wt.why.chlorine-taste":"remove the oxidant taste after dosing","wt.why.fe":"iron {v} mg/l — a softener accepts at most 0.2","wt.why.mn":"manganese {v} mg/l — a softener accepts at most 0.05","wt.why.hard":"hardness {v} meq/l → keep ≈{r} with the blending valve","wt.why.hard-opt":"hardness {v} meq/l — optional; needed if the water heater runs above 60 °C","wt.why.ro-feed-hard":"hardness before RO must be at most {lim} meq/l","wt.why.ox":"oxidisability {v} mg O₂/l (limit {lim}) — organics foul resin and membranes","wt.why.cl2":"free chlorine {v} mg/l — damages the RO membrane","wt.why.tds":"TDS {v} mg/l (above {lim}) — a softener will not lower it","wt.why.cl":"chlorides {v} mg/l (limit {lim})","wt.why.so4":"sulphates {v} mg/l (limit {lim})","wt.why.no3":"nitrates {v} mg/l (limit {lim})","wt.why.sodium":"sodium after softening ≈{v} mg/l (limit {lim})","wt.why.poe":"TDS {v} mg/l — above {lim}, the well-water limit of the chosen country","wt.why.micro":"coliforms or E.coli found","wt.why.micro-unknown":"no microbiology test — UV as insurance","wt.warn.incomplete":"Incomplete analysis: missing {missing} — the selection is approximate","wt.warn.bad-value":"Parameter “{param}” is not a number — skipped","wt.warn.bad-unit":"Parameter “{param}”: unknown unit “{unit}” — skipped","wt.warn.tds-from-ec":"TDS estimated from conductivity (×0.65)","wt.warn.no-hardness":"No hardness in the analysis — no softener selected","wt.warn.residual-low":"Residual hardness {r} meq/l: below 1.5 the water becomes aggressive to pipes — ≈3 is better","wt.warn.hard-over-15":"Hardness {v} meq/l exceeds a household softener’s limit (15) — check with the manufacturer","wt.warn.tds-softener-no":"A softener does not lower TDS: {v} mg/l remains, calcium and magnesium are only swapped for sodium","wt.warn.tds-softener-weak":"TDS {v} mg/l: above 3000 a household softener barely works — a design is needed","wt.warn.na-unknown":"No sodium in the analysis: softening will add ≈{d} mg/l — check whether it is drinkable","wt.warn.sodium-drink":"Sodium after softening ≈{v} mg/l (limit 200): do not drink softened water — kitchen RO or a raw-water tap","wt.warn.poe-ro":"Whole-house RO: ≈{conc} l/day of concentrate, pre-treatment required, costlier to buy and run","wt.warn.birm-ph":"pH {v} below 6.8 — catalytic media will not work; greensand chosen (or pH correction)","wt.warn.birm-ox":"Oxidisability {v} is too high for catalytic media; greensand chosen","wt.warn.birm-mn":"Birm removes manganese only at pH {ph}+ (manufacturer sheet) — manganese-dioxide media chosen (DBN V.2.5-74 cl. 10.23)","wt.warn.mno2-oxidant":"The maker of MnO₂ media recommends an oxidant before the column — air via an injector or chlorine (after chlorine, carbon before resin and membranes); heavy backwash — check against the well pump","wt.warn.hard-x2":"Hardness {v} does not match the report’s calcium and magnesium: Ca/20.04 + Mg/12.15 = {calc} meq/l — twice as much. The report seems to give true mmol/l: choose “mmol/l (DE/EU)” or enter {calc}. Until then we calculate with {v} — salt, waste and sodium are halved","wt.warn.hard-x2-ions":"The report’s ion balance is off ({d} %) but balances with doubled hardness (≈{calc} meq/l): the report seems to give true mmol/l. Choose “mmol/l (DE/EU)” or enter ≈{calc}; until then we use {v}","wt.warn.hard-half":"Hardness {v} meq/l is twice what the rest of the report gives (≈{calc}): probably “mmol/l (DE/EU)” was chosen while the report gives meq/l — check the unit","wt.warn.hard-mismatch":"Hardness {v} does not match the report’s calcium and magnesium (≈{calc} meq/l) — check the report","wt.warn.ion-balance":"The report’s ion balance is off ({d} %) — an error in the report or a missing parameter; the selection is approximate","wt.warn.greensand-waste":"Greensand is regenerated with potassium permanganate — backwash must not go to an aerobic unit","wt.warn.carbon-o2":"Catalytic carbon needs dissolved oxygen ≥4 mg/l — usually not in the report, check","wt.warn.feed-violation":"Before “{stage}” {param} = {v}, but at most {lim} is allowed — extra pre-treatment needed","wt.warn.micro-unknown":"No microbiology test: for drinking water test separately (coliforms, E.coli) in a sterile bottle","wt.warn.uv-dose-low":"UV dose {v} mJ/cm² — below 40 (class A) for a well","wt.warn.uv-no-sensor":"UV without an intensity sensor — you cannot see when the lamp weakens","wt.warn.ro-no-mineralizer":"RO produces “empty” water of 20–30 mg/l — a mineraliser is better for drinking","wt.warn.magnetic-no-effect":"Magnetic and electronic “softeners” do not reduce hardness — no proven effect (DVGW)","wt.warn.brine-soakaway":"Salty backwash ≈{lo}–{hi} l/day: not into an aerobic unit; a separate soakaway at least 20 m from the well","wt.param.tds":"Total dissolved solids","wt.param.hard":"Total hardness","wt.param.ca":"Calcium","wt.param.mg":"Magnesium","wt.param.na":"Sodium","wt.param.k":"Potassium","wt.param.hco3":"Bicarbonates","wt.param.cl":"Chlorides","wt.param.so4":"Sulphates","wt.param.fe":"Total iron","wt.param.mn":"Manganese","wt.param.ox":"Permanganate oxidisability, mg O₂/l","wt.param.no3":"Nitrates","wt.param.h2s":"Hydrogen sulphide","wt.param.ph":"pH","wt.param.turb":"Turbidity","wt.param.cl2":"Free chlorine (mains water)","wt.param.coli":"Total coliforms","wt.param.ecoli":"E.coli","wt.param.sio2":"Silica (as SiO₂)","wt.param.ba":"Barium","wt.param.sr":"Strontium","wt.param.f":"Fluoride","mb.type.ro":"Low-pressure reverse osmosis (type XLE / ULP)","mb.type.nf-tight":"Tight nanofiltration (type NF90)","mb.type.nf-loose":"Loose nanofiltration (type NF270)","mb.use.ro":"drinking water in every tap — permeate is “empty”, add raw-water blending or a mineraliser","mb.use.nf-tight":"drinking water with a little blending; chloride removal depends on the water","mb.use.nf-loose":"softening and sulphates — technical water (shower, laundry); passes most sodium and chloride","mb.typeDesc.ro":"{use}. Retains hardness ≈{hard} %, sulphates ≈{so4} %, sodium ≈{na} %, chlorides ≈{cl} %; feed pressure ≈{p} bar","mb.typeDesc.nf-tight":"{use}. Retains hardness ≈{hard} %, sulphates ≈{so4} %, sodium ≈{na} %, chlorides ≈{cl} %; feed pressure ≈{p} bar","mb.typeDesc.nf-loose":"{use}. Retains hardness ≈{hard} %, sulphates ≈{so4} %, sodium ≈{na} %, chlorides ≈{cl} %; feed pressure ≈{p} bar","mb.by.lsi":"calcium carbonate (Langelier index of the concentrate)","mb.by.caso4":"gypsum (CaSO₄)","mb.by.sio2":"silica","mb.by.baso4":"barium sulphate","mb.by.srso4":"strontium sulphate","mb.by.caf2":"calcium fluoride","mb.by.cap":"practical limit of a household system (60–75 %)","mb.by.design":"design recovery 70 % — a margin for unmeasured barium, strontium and silica","mb.by.user":"your value","mb.warn.temp-assumed":"Water temperature not given — calculated for {t} °C; measure the coldest well water (lower = more pressure and silica risk)","mb.warn.ca-assumed":"No calcium in the analysis — all hardness taken as calcium (conservative for scaling)","mb.warn.nochem-flush":"Without antiscalant or softening: only ≈{y} % recovery with frequent flushing, elements last 1–2 years (limited by {by})","mb.warn.recovery-over":"Recovery {y} % exceeds the limit {lim} % ({by}) — scaling risk","mb.warn.no-recovery":"Recovery only {y} % — limited by {by}; change pretreatment","mb.warn.lsi-unknown":"Calcium carbonate scaling not checked — missing: {missing}","mb.warn.not-measured":"Not measured: {params} — assumed 0; they can limit recovery, worth adding to the analysis","mb.warn.feed-violation":"Before the membrane {param} = {v}, allowed {lim} — more pretreatment needed","mb.warn.cl2-damages":"Free chlorine {v} mg/l destroys the membrane (allowed {lim}) — a carbon filter before it","mb.warn.type-tech":"{type}: not drinking quality ({list}) — technical water only","mb.warn.type-uncertain":"{type}: in the worse case of the source range {params} exceed the limit — check with the manufacturer projection","mb.warn.blend-none":"{type}: no blending share meets all limits ({k})","mb.warn.tap-over":"Tap water above drinking limits: {list}","mb.warn.below-physio":"Tap water below the physiological adequacy of the Ukrainian DSanPiN (annex 4), used as guidance: {list}","mb.warn.below-anses":"Below ANSES recommendation after NF/RO (≥ 8 °f hardness and alkalinity): {list}","mb.warn.aggressive":"Water is aggressive (Langelier index {cold} cold, {hot} hot) — dissolves the protective layer in metal pipes and the boiler; blending or a mineraliser is advised","mb.warn.remin-yield":"How much calcite dissolves depends on permeate CO₂/pH (calcite works on water with pH 5–7) and contact time — check by analysis after the mineraliser","mb.warn.sink-ask":"Where will the concentrate (≈{l} l/day) go: a soakaway on the plot, the sewer/septic tank or elsewhere?","mb.warn.projection":"Estimate from datasheets and pilots; for a warranty — the manufacturer projection program","mb.advice.conc-septic-over":"Concentrate {v} l/day — more than {max} l/day that US practice considers insignificant for a septic tank: a separate soakaway is better","mb.advice.conc-septic-ok":"Concentrate {v} l/day — within {max} l/day considered insignificant for a septic tank (US practice)","mb.advice.conc-soakaway":"Separate soakaway: at least {dist} m from the well (by analogy with sewer structures — no norm for concentrate itself) and ≥ {soil} m of soil above groundwater (Polish norm)","mb.advice.conc-central":"Into the sewer together with household waste water (allowed if treatable together)","mb.advice.conc-other":"Other discharge — check local rules","mb.prop.blend":"Blend {pct} % raw water (after iron/manganese removal); allowed range {lo}–{hi} %","mb.prop.remin":"Mineraliser (calcite / marble chips): +{add} meq/l calcium, ≈{kg} kg CaCO₃ per year","mb.prop.uv":"UV after blending — raw water microbiology is unknown (option)","mb.buy.dosing":"Antiscalant dosing station (proportional)","mb.buy.prefilter5":"5 µm prefilter housing","mb.buy.unit":"RO/NF unit 250 l/h for one 4040 element","mb.buy.element":"Membrane element 4040","mb.buy.controller":"Controller with conductivity meter","mb.buy.tank":"Permeate tank","mb.buy.float":"Tank float switch","mb.buy.booster":"Second-lift pump station (inverter)","mb.buy.remineralizer":"Mineraliser column (calcite)","mb.buy.install":"Installation and commissioning","mb.buy.softener":"Softener before the membrane","mb.year.electricity":"Electricity","mb.year.element":"Membrane element (once per ≤ 3 years)","mb.year.antiscalant":"Antiscalant (new pack every year — shelf life)","mb.year.cip":"Chemical cleaning (service)","mb.year.cartridges":"5 µm cartridges","mb.year.calcite":"Calcite for the mineraliser","mb.year.salt":"Softener salt","wt.short.mech":"Sediment filter","wt.short.h2s":"H₂S removal","wt.short.iron":"Iron filter","wt.short.carbon":"Carbon filter","wt.short.complex":"Combined filter","wt.short.softener":"Softener","wt.short.ro_poe":"Whole-house RO","wt.short.ro_pou":"Under-sink RO","wt.short.uv":"UV lamp","px.approx":"approximate — converted from Ukrainian prices at the NBU rate of {date}","px.stale":" (the last known rate — a fresh one could not be fetched)","px.mark":"≈","px.country":"Estimate country","px.state":"State","px.stateAny":"other / not sure","px.by.site":"chosen for this plan","px.by.detected":"detected from your location — change it if you are building in another country","px.by.default":"default","px.noRate":"the NBU rate is unavailable right now — prices are in UAH (Ukraine)","px.noFactors":"no factors for this country yet — prices are in UAH (Ukraine)","px.uah":"Ukrainian prices, UAH","px.local":"local price of this country (its price list)","px.US.h":"US: what these rows do not include","px.US.permits":"A building permit from the local municipality (county / city): fees from a few hundred to several thousand dollars.","px.US.inspections":"Inspections at each stage (foundation, framing, MEP, final); work without a permit means fines and trouble selling the house.","px.US.contractor":"A licensed and insured general contractor — the insurance is built into their prices.","px.US.states":"Prices differ 1.5–2× between states; we account for three groups of states only (high-cost, low-cost, the rest).","px.US.timber":"US homes are mostly timber frame, while our estimate assumes masonry walls — the scope of work and the prices will differ.","px.US.notInRows":"These items are not in the rows.","ui.analysis":"Water test results","ui.analysisHint":"Copy the numbers from your well water lab report and pick the unit it uses (hardness in gpg or mg/L as CaCO₃; ppm = mg/L). An empty field means «not measured», not zero.","ui.moreParams":"Other parameters of the report","ui.mainMark":"key parameter","ui.options":"House","ui.source":"Water source","ui.src.well":"private well","ui.src.tap":"public water system","ui.persons":"Occupants","ui.prem":"Equipment level, %","ui.premHint":"0 — the simplest, 50 — balanced, 100 — no compromise","ui.hot":"Water heater above 60 °C","ui.accept":"Also install","ui.acc.ro_poe":"whole-house reverse osmosis","ui.acc.uv":"UV disinfection","ui.net":"No connection to the server — please try again.","ui.fail":"Could not calculate — please check the fields.","ui.empty":"Enter at least a few values from the report — the selection starts at once.","ui.missing":"Missing: {list} — the selection is approximate.","ui.chain":"Equipment in the order the water flows","ui.need.required":"required","ui.need.recommended":"recommended","ui.need.optional":"optional","ui.offered":"offered — not included","ui.place.kitchen":"under the kitchen sink","ui.place.tech":"plant room","ui.priceNotFound":"no price found — ask the seller","ui.feedIssue":"at the inlet: {param} {v} where {lim} is allowed","ui.total":"Equipment total ≈ {sum}","ui.totalYear":"Consumables per year ≈ {sum}","ui.pricesNote":"Prices — Ukraine, {asof}, approximate, from our source registry; installation not included.","ui.drinking.house":"Drinking water — the house water after the equipment; only a lab test after installation can confirm it.","ui.market":"Country (quality limits and prices)","ui.market.UA":"Ukraine — DSanPiN limits, prices in UAH","ui.market.US":"United States — EPA standards as a guide, prices in USD","ui.market.UK":"United Kingdom — Private Water Supplies Regulations 2016, prices in GBP","ui.market.unsupported":"We have no limits or prices for your country ({cc}) yet — pick the closest one.","ui.limits.UA":"Quality limits — DSanPiN 2.2.4-171-10 (Ukraine).","ui.limits.US":"Private wells are not regulated by EPA; your water is compared with EPA public-water standards (secondary ones are non-enforceable) as a guide.","ui.limits.UK":"Limits — the Private Water Supplies (England) Regulations 2016; Wales, Scotland and Northern Ireland have their own regulations — check with your local council.","ui.noLocalPrice":"no local price found","ui.installed":"installed","ui.sumFound":"sum of the prices found only","ui.localPrices":"Prices for this country (found in sources)","ui.uahOnly":"Itemised prices of the unit are in our registry for Ukraine only (UAH) — we do not convert them.","ui.paste.h":"Or paste the text of your lab report","ui.paste.ph":"Copy the text of the lab report here (from a PDF or an e-mail)","ui.paste.btn":"Read the values","ui.paste.busy":"Reading…","ui.paste.ok":"Values found: {n} — please compare with the report.","ui.paste.none":"No values found in the text — please type them in.","ui.paste.unavailable":"Reading text is not available right now — please type the values in.","ui.drinking.ro":"For drinking and cooking — reverse osmosis under the sink; other taps get the house water after the equipment.","ui.drinking.ro-house":"Every tap gets water after whole-house reverse osmosis.","ui.flows":"Water and discharges","ui.qDay":"House water ≈ {q} m³/day ({p} people)","ui.brine":"Softener regeneration brine ≈ {lo}–{hi} L/day; salt ≈ {salt} kg/year","ui.backwash":"Iron filter backwash — not salty{perm}","ui.backwashPerm":" (with permanganate — not into a treatment plant)","ui.concPou":"Under-sink RO concentrate ≈ {l} L/day","ui.concPoe":"Whole-house RO concentrate ≈ {l} L/day","ui.yearly":"Every year","ui.y.salt":"Salt tablets, {q} kg","ui.y.roPrefilters":"RO pre-filters (every 3 months)","ui.y.uvLamp":"UV lamp (every 10–12 months)","ui.warnings":"What to keep in mind","ui.sources":"sources","ui.notClaim":"What this calculation does not claim","ui.notClaim.1":"That the water is «safe to drink» or «meets the standard»: the calculator gives equipment estimates from the values you enter; only a certified laboratory test AFTER installation can confirm the water.","ui.notClaim.2":"That it replaces a design or the manufacturer's warranty: check capacity, pressure and media against the device data sheet and the manufacturer's projection.","ui.notClaim.3":"That prices are final: they are open prices on the date, without installation and delivery.","ui.toMembrane":"Size whole-house reverse osmosis / nanofiltration for this water →","ui.toWater":"Choose the full treatment chain for this water →","ui.guides":"Read more:","ui.mb.water":"Water and mode","ui.mb.type":"Membrane type","ui.mb.type.auto":"auto — the loosest one that still gives drinking water in the worst case","ui.mb.mode":"Water at the tap","ui.mb.mode.none":"permeate only (no blending)","ui.mb.mode.blend":"permeate + blended feed water","ui.mb.mode.remin":"permeate through a remineraliser (calcite)","ui.mb.blendPct":"Blending share, %","ui.mb.recovery":"Recovery, %","ui.mb.recoveryPh":"70 by default","ui.mb.tempC":"Coldest water, °C","ui.mb.tempPh":"10 if not measured","ui.mb.m3Day":"Water per day, m³","ui.mb.m3DayPh":"empty — 150 L per person","ui.mb.anti":"Antiscalant","ui.mb.anti.auto":"auto — when the recovery cannot be reached without it","ui.mb.anti.yes":"yes","ui.mb.anti.no":"no (frequent flushing only)","ui.mb.pre":"Softener before the membrane","ui.mb.sink":"Where the concentrate goes","ui.mb.sink.":"not decided yet","ui.mb.sink.soakaway":"a separate soakaway on the plot","ui.mb.sink.septic":"septic tank / on-site sewage","ui.mb.sink.central":"public sewer","ui.mb.sink.other":"other","ui.mb.typeH":"Membrane","ui.mb.verdict.drink":"drinking water without correction","ui.mb.verdict.correct":"drinking water after remineralisation","ui.mb.verdict.tech":"service water only","ui.mb.recoveryLine":"Recovery {y} % — limited by: {by}; antiscalant: {anti}","ui.mb.yes":"yes","ui.mb.no":"no","ui.mb.regime.flush":"No-chemicals mode: frequent forward flushing, elements last 1–2 years.","ui.mb.pre.stages":"Pre-treatment before the membrane: {list}","ui.mb.tap":"Water at the tap","ui.mb.th.param":"Parameter","ui.mb.th.feed":"Feed","ui.mb.th.tap":"At the tap","ui.mb.th.lim":"Limits","ui.mb.limMax":"≤ {v}","ui.mb.limMin":"≥ {v}","ui.mb.alk":"Alkalinity","ui.mb.lsi":"Langelier index: cold {c}, hot {h} (below 0 — the water is aggressive to metal pipes and the heater)","ui.mb.proposals":"Remineralisation — your choice (nothing is blended automatically)","ui.mb.prop.blend":"Blend feed water: {pct} % (allowed {lo}–{hi} %)","ui.mb.prop.blendHow":"How it is done: a bypass with a regulating valve and a meter after iron removal — part of the feed water goes past the membrane into the permeate tank. Raw water reaches the tap → UV disinfection after the blend.","ui.mb.prop.uv":"UV after the blend: ≈ {price}; lamp ≈ {lamp} per year","ui.mb.prop.remin":"Remineraliser (calcite, marble chips): +{add} meq/L calcium, ≈ {kg} kg per year","ui.mb.prop.reminHow":"How it is done: a calcite column after the permeate tank — water passes the media and picks up calcium and bicarbonate; the media is topped up once a year; check with a test after the column.","ui.mb.prop.reminCost":"Media ≈ {cost} per year ({perKg}/kg); no price found for a whole-house column.","ui.mb.prop.left":"Does not fix: {list}","ui.mb.volumes":"Volumes, m³/day","ui.mb.v.permeate":"permeate","ui.mb.v.bypass":"blend","ui.mb.v.feed":"feed water to the membrane","ui.mb.v.concentrate":"concentrate","ui.mb.v.withdraw":"drawn from the well","ui.mb.conc":"Concentrate ≈ {l} L/day, TDS ≈ {tds} mg/L","ui.mb.sizing":"Membrane elements","ui.mb.size":"{n} × {size} ({area} m²) — ≈ {h} h/day, permeate {perm} L/h","ui.mb.recirc":"; concentrate recirculation ≈ {l} L/h","ui.mb.est":" (estimate)","ui.mb.pressure":"Feed pressure ≈ {bar} bar (estimate)","ui.mb.energy":"Electricity ≈ {lo}–{hi} kWh/year","ui.mb.tank":"Permeate tank {l} L × {n}, booster pump","ui.mb.antiLine":"Antiscalant {d0}–{d1} mg/L (drinking-water ceiling {max}) → ≈ {k0}–{k1} kg/year","ui.mb.cip":"Chemical cleaning {lo}–{hi} times a year (estimate). Water for acid / citric cleaning — {min}–{acid} °C, for nanofiltration by the data sheet up to {nf} °C; owners' practice «up to {practice} °C» is on the edge: the manufacturer forbids 50 °C, 60 °C destroys the membrane.","ui.mb.cart":"5 µm cartridges — every {mlo}–{mhi} months depending on the water ({lo}–{hi} per year); by the rated capacity it would be {vol} per year.","ui.mb.buy":"Purchase","ui.mb.buyMissing":"No price (not found): {list}","ui.mb.yearH":"Every year ≈ {lo}–{hi}","ui.mb.compare":"Compared with «softener + under-sink reverse osmosis»","ui.mb.cmp.softener":"Softener + under-sink RO: purchase ≈ {buy}, year ≈ {year}; at the taps sodium ≈ {na} mg/L, TDS ≈ {tds} mg/L","ui.mb.cmp.membrane":"Whole-house membrane: purchase ≈ {buy}, year ≈ {lo}–{hi}; at the taps sodium ≈ {na} mg/L, TDS ≈ {tds} mg/L","ui.mb.scale":"What limits the recovery (concentrate at different recoveries)","ui.mb.th.y":"Recovery","ui.mb.th.tds":"Concentrate, mg/L","ui.mb.th.caso4":"Gypsum, % saturation","ui.mb.th.lsi":"LSI","ui.mb.th.sio2":"SiO₂, mg/L","ui.mb.th.pi":"Osmotic pressure, bar","ui.mb.descTitle":"What it does","ui.buyRow.pre":"Pre-treatment — {name}","ui.lead.h":"Get the sizing report link by e-mail","ui.lead.p":"Enter your e-mail to get a link to the complete sizing, flow rates and equipment list for your water. You can also upload a photo of your lab report (a PDF needs an account): the answer to an uploaded report comes later.","ui.lead.file":"Lab report: photo or PDF (up to 10 MB)","ui.lead.email":"E-mail","ui.lead.consent":"By sending, you agree that Dwelvia stores your test results and e-mail to send this calculation — no marketing e-mails. We keep them 12 months and delete them on request («Delete my data» on the link in the e-mail).","ui.lead.privacy":"Privacy Policy","ui.lead.privacyHref":"/guides/politika-konfidentsiynosti-en","ui.lead.pdfRegister":"A PDF needs an account — sign in or register; the answer comes by e-mail later.","ui.lead.delete":"Delete my data","ui.lead.deleteAsk":"Delete the saved test results and e-mail for good?","ui.lead.deleteYes":"Yes, delete","ui.lead.deleteNo":"No","ui.lead.deleted":"Your data has been deleted.","ui.lead.send":"Send","ui.lead.or":"or","ui.lead.register":"create an account — your calculations stay in your workspace","ui.lead.sending":"Sending…","ui.lead.ok":"Done. The link has been sent to {email}.","ui.lead.okPending":"Received. As soon as the calculation is ready, we will send the link to {email}.","ui.lead.okNoMail":"Saved. E-mail is unavailable right now — here is the link: {link}","ui.lead.needEmail":"Please enter your e-mail.","ui.lead.needConsent":"Consent to store the data is required.","ui.lead.needData":"Add the report file or type the values above.","ui.lead.loaded":"Opened a saved calculation from {date}.","ui.lead.recognized":"The values come from your report — please compare with the original.","ui.lead.waiting":"The calculation is still being prepared — the link comes by e-mail as soon as it is ready.","ui.lead.fileType":"A photo (JPG, PNG, WEBP, HEIC) or a PDF, please.","ui.lead.fileSize":"The file is larger than 10 MB — compress the photo or send the pages separately.","ui.lead.rate":"Too many attempts — please try again in an hour.","ui.lead.signedIn":"You are signed in — we will send it to {email}.","unit.mg/l":"mg/L","unit.uS/cm":"µS/cm","unit.meq":"meq/L (= «mmol/L» in Ukrainian reports)","unit.mmol_eu":"mmol/L (EU/DE)","unit.dH":"°dH","unit.fH":"°f","unit.caco3":"mg/L as CaCO₃ (= ppm)","unit.gpg":"gpg (grains per gallon)","unit.ug/l":"µg/L","unit.ntu":"NTU","unit.cfu":"CFU/100 mL","unit.si":"mg/L as Si","money":"{n} UAH","dec":"."},"op":"water","fields":{"source":{"type":"enum","options":["well","tap"],"form":{"id":"source","store":"w_source","label":"ui.source","control":"select","box":"opts"}},"persons":{"type":"int","form":{"id":"persons","store":"persons","label":"ui.persons","box":"opts"}},"prem":{"type":"num","form":{"id":"prem","store":"prem","label":"ui.prem","ph":"ui.premHint","box":"opts"}},"cls":{"type":"enum","options":["budget","standard","premium"],"form":null},"hotOver60":{"type":"bool","form":{"id":"hotOver60","store":"w_hot","label":"ui.hot","control":"check","box":"opts"}},"accept":{"type":"list","options":["ro_poe","uv","softener","complex"],"form":{"id":"acc","store":false,"label":"ui.accept","control":"checks","formOptions":["ro_poe","uv"],"optionIds":{"ro_poe":"acc_ro_poe","uv":"acc_uv"},"box":"opts"}},"existing":{"type":"list","options":["magnetic"],"form":null}},"refs":{"water_treatment.FR.anses-ro-remineralise-8f":{"d":"Avis de l'Anses, saisine n° 2024-SA-0136 (16 mai 2025) — modules de filtration membranaire (arrêté du 22 juin 2012, CSP R1321-50)","c":"","u":"https://www.anses.fr/system/files/EAUX2024-SA-0136.pdf","k":"recommendation"},"water_quality.US.sm2340b-hardness-calc":{"d":"Standard Methods 2340 B «Hardness by Calculation» (NEMI method summary 4679)","c":"Brief Method Summary","u":"https://nemi.gov/methods/method_summary/4679","k":"recommendation"},"water_treatment.UA.ecosoft-fu-feed":{"d":"ecosoft.ua","c":"","u":"https://ecosoft.ua/ua/filtr-umyagcheniya-vody-ecosoft-fu1054ci/","k":"recommendation"},"water_treatment.UA.ecomix-feed":{"d":"ecosoft.ua","c":"","u":"https://ecosoft.ua/ua/filtr-obezzhelezivaniya-i-umyagcheniya-vody-ecosoft-fk1054cimixa/","k":"recommendation"},"water_treatment.UA.ecosoft-ro-feed":{"d":"ecosoft.ua","c":"","u":"https://ecosoft.ua/ua/filtr-obratnogo-osmosa-ecosoft-standard-pro-s-pompoy/","k":"recommendation"},"water_treatment.UA.dbn74-ro-feed":{"d":"document.vobu.ua","c":"","u":"https://document.vobu.ua/wp-content/uploads/DBN/101.1.-DBN-V.2.5-742013.-Vodopostachannya.-Zovnishni-merezhi.pdf","k":"norm"},"cost.UA.ro-uv-2026":{"d":"ecosoft.ua","c":"","u":"https://ecosoft.ua/ua/commercial-ro-ecosoft-mo-5000/","k":"price"},"membrane.INT.filmtec-feedwater-quality-table15":{"d":"DuPont FilmTec Reverse Osmosis Membranes Technical Manual, Form No. 45-D01504-en, Rev. 20, August 2026","c":"","u":"https://www.dupont.com/content/dam/water/amer/us/en/water/public/documents/en/RO-NF-FilmTec-Manual-45-D01504-en.pdf","k":"recommendation"},"water_treatment.US.uv-feed-county":{"d":"Chautauqua County (NY) Environmental Health Services — Private Drinking Water Standard for Ultra Violet (UV) Light Disinfection System","c":"Water Quality; installer checklist","u":"https://chautauquacountyny.gov/sites/default/files/inline-files/Private%20UV%20Light%20Disinfection%20System%20Requirements.pdf","k":"norm"},"membrane.INT.nf270-4040-datasheet":{"d":"DuPont FilmTec NF270 Element, Product Data Sheet, Form No. 45-D01529-en, Rev. 8, January 2025","c":"Typical Properties; Suggested Operating Conditions","u":"https://www.dupont.com/content/dam/water/amer/us/en/water/public/documents/en/NF-FilmTec-NF270-PDS-45-D01529-en.pdf","k":"recommendation"},"membrane.INT.nf90-4040-datasheet":{"d":"Dow FILMTEC NF90-4040 Membranes, Product Specifications, Form No. 609-00378-1206 (2006) + DuPont FilmTec NF90 Element PDS, Form No. 45-D01520-en, Rev. 8, April 2026","c":"Product Specifications; Operating Limits; General Information","u":"https://www.lenntech.com/Data-sheets/Dow-Filmtec-NF90-4040.pdf","k":"recommendation"},"membrane.INT.xle-pro-4040-datasheet":{"d":"DuPont FilmTec XLE PRO-4040 & XLE PRO-2540 Element, Product Data Sheet, Form No. 45-D03972-en, Rev. 6, April 2026","c":"Typical Properties; Suggested Operating Conditions","u":"https://www.dupont.com/content/dam/water/amer/us/en/water/public/documents/en/RO-FilmTec-XLE-PRO-4040-and-XLE-PRO-2540-PDS-45-D03972-en.pdf","k":"recommendation"},"membrane.INT.filmtec-pressure-rejection-by-type":{"d":"DuPont FilmTec Reverse Osmosis Membranes Technical Manual, Form No. 45-D01504-en, Rev. 20, August 2026","c":"","u":"https://www.dupont.com/content/dam/water/amer/us/en/water/public/documents/en/RO-NF-FilmTec-Manual-45-D01504-en.pdf","k":"recommendation"},"membrane.INT.bw30-pro-4040-datasheet":{"d":"DuPont FilmTec BW30 PRO-4040 & BW30 PRO-2540 Element, Product Data Sheet, Form No. 45-D03970-en, Rev. 5, October 2024","c":"Typical Properties; Suggested Operating Conditions","u":"https://www.dupont.com/content/dam/water/amer/us/en/water/public/documents/en/RO-FilmTec-BW30-PRO-4040-and-BW30-PRO-2540-PDS-45-D03970-en.pdf","k":"recommendation"},"membrane.INT.nf90-groundwater-ion-rejection":{"d":"Emamjomeh M.M., Torabi H., Mousazadeh M., Alijani M., Gohari F. «Impact of independent and non-independent parameters on various elements' rejection by nanofiltration employed in groundwater treatment», Applied Water Science 9 (2019) 71, doi:10.1007/s13201-019-0949-1","c":"","u":"https://link.springer.com/article/10.1007/s13201-019-0949-1","k":"practice"},"membrane.INT.nf270-bicarbonate-rejection":{"d":"pmc.ncbi.nlm.nih.gov","c":"","u":"https://pmc.ncbi.nlm.nih.gov/articles/PMC13414083/","k":"practice"},"membrane.INT.nf270-ion-rejection-pilot":{"d":"Tariqi A.Q., Cruzado L., Straub A.P., Hickenbottom K.L., …, Karanikola V. «Synergistic solutions: reverse osmosis and nanofiltration configurations for efficient brackish water desalination», npj Clean Water 8, 83 (2025)","c":"","u":"https://www.nature.com/articles/s41545-025-00515-w","k":"practice"},"membrane.INT.dupont-nf-rejection-ranges":{"d":"dupont.com","c":"","u":"https://www.dupont.com/water/technologies/nanofiltration-nf.html","k":"recommendation"},"membrane.UA.term-nanofiltratsiia":{"d":"document.vobu.ua","c":"","u":"https://document.vobu.ua/wp-content/uploads/DBN/101.1.-DBN-V.2.5-742013.-Vodopostachannya.-Zovnishni-merezhi.pdf","k":"norm"},"water_treatment.DE.dvgw-residual-hardness":{"d":"DVGW-Kompaktinfo «Wasseraufbereitung in der Trinkwasserinstallation» (März 2024)","c":"Enthärtungsanlagen","u":"https://www.dvgw.de/medien/dvgw/leistungen/publikationen/twin-wasseraufbereitung-trinkwasserinstallation-maerz-2024.pdf","k":"recommendation"},"water_treatment.US.sodium-per-gpg":{"d":"products.geappliances.com","c":"","u":"https://products.geappliances.com/appliance/gea-support-search-content?contentId=18720","k":"recommendation"},"membrane.INT.scale-lsi-limits":{"d":"DuPont FilmTec Reverse Osmosis Membranes Technical Manual, Form No. 45-D01504-en, Rev. 20 (August 2026)","c":"§2.4.2.1 Brackish Water, «Adjustments of LSIc», p. 37","u":"https://www.dupont.com/content/dam/dupont/amer/us/en/water-solutions/public/documents/en/RO-NF-FilmTec-Manual-45-D01504-en.pdf","k":"recommendation"},"membrane.INT.antiscalant-limits-vitec":{"d":"lenntech.com","c":"","u":"https://www.lenntech.com/Data-sheets/Avista-Vitec-2000-antiscalant-datasheet-L.pdf","k":"recommendation"},"membrane.US.scale-astm-d3739-lsi":{"d":"ASTM D3739-19 Standard Practice for Calculation and Adjustment of the Langelier Saturation Index for Reverse Osmosis","c":"Scope 1.1","u":"https://store.astm.org/d3739-19.html","k":"norm"},"membrane.INT.scale-lsi-sdsi-choice":{"d":"DuPont FilmTec Reverse Osmosis Membranes Technical Manual, Form No. 45-D01504-en, Rev. 20 (August 2026)","c":"§2.3.2 Acid Addition, p. 32; §2.4.2.1–2.4.2.2, pp. 36, 40","u":"https://www.dupont.com/content/dam/dupont/amer/us/en/water-solutions/public/documents/en/RO-NF-FilmTec-Manual-45-D01504-en.pdf","k":"recommendation"},"membrane.INT.scale-caso4-limit":{"d":"DuPont FilmTec Reverse Osmosis Membranes Technical Manual, Form No. 45-D01504-en, Rev. 20 (August 2026)","c":"§2.4.3 Calcium Sulfate Scale Prevention, step 3 and «Adjustments», pp. 43–44","u":"https://www.dupont.com/content/dam/dupont/amer/us/en/water-solutions/public/documents/en/RO-NF-FilmTec-Manual-45-D01504-en.pdf","k":"recommendation"},"membrane.INT.scale-ksp-table":{"d":"DuPont FilmTec Reverse Osmosis Membranes Technical Manual, Form No. 45-D01504-en, Rev. 20 (August 2026)","c":"§2.3.1, Table 11 «Solubility products of sparingly soluble inorganic compounds», pp. 31–32; Figure 21 p. 45","u":"https://www.dupont.com/content/dam/dupont/amer/us/en/water-solutions/public/documents/en/RO-NF-FilmTec-Manual-45-D01504-en.pdf","k":"recommendation"},"membrane.INT.scale-cf-recovery":{"d":"DuPont FilmTec Reverse Osmosis Membranes Technical Manual, Form No. 45-D01504-en, Rev. 20 (August 2026)","c":"§2.4.1 General, Eq. 2–5, p. 35","u":"https://www.dupont.com/content/dam/dupont/amer/us/en/water-solutions/public/documents/en/RO-NF-FilmTec-Manual-45-D01504-en.pdf","k":"recommendation"},"membrane.INT.scale-silica":{"d":"DuPont FilmTec Reverse Osmosis Membranes Technical Manual, Form No. 45-D01504-en, Rev. 20 (August 2026)","c":"§2.4.7 Silica Scale Prevention, Eq. 29, Figures 25–26, pp. 50–54","u":"https://www.dupont.com/content/dam/dupont/amer/us/en/water-solutions/public/documents/en/RO-NF-FilmTec-Manual-45-D01504-en.pdf","k":"recommendation"},"membrane.INT.scale-baso4-srso4":{"d":"DuPont FilmTec Reverse Osmosis Membranes Technical Manual, Form No. 45-D01504-en, Rev. 20 (August 2026)","c":"§2.4.4 Barium Sulfate, §2.4.5 Strontium Sulfate, pp. 45–46","u":"https://www.dupont.com/content/dam/dupont/amer/us/en/water-solutions/public/documents/en/RO-NF-FilmTec-Manual-45-D01504-en.pdf","k":"recommendation"},"membrane.INT.scale-caf2":{"d":"DuPont FilmTec Reverse Osmosis Membranes Technical Manual, Form No. 45-D01504-en, Rev. 20 (August 2026)","c":"§2.4.6 Calcium Fluoride Scale Prevention, p. 46","u":"https://www.dupont.com/content/dam/dupont/amer/us/en/water-solutions/public/documents/en/RO-NF-FilmTec-Manual-45-D01504-en.pdf","k":"recommendation"},"water_quality.UA.dsanpin-dry-residue":{"d":"zakon.rada.gov.ua","c":"","u":"https://zakon.rada.gov.ua/laws/show/z0452-10/print","k":"norm"},"water_quality.UA.dsanpin-hardness":{"d":"zakon.rada.gov.ua","c":"","u":"https://zakon.rada.gov.ua/laws/show/z0452-10/print","k":"norm"},"water_quality.UA.dsanpin-cl-so4-na":{"d":"zakon.rada.gov.ua","c":"","u":"https://zakon.rada.gov.ua/laws/show/z0452-10/print","k":"norm"},"water_quality.UA.dsanpin-n-ph-organics":{"d":"zakon.rada.gov.ua","c":"","u":"https://zakon.rada.gov.ua/laws/show/z0452-10/print","k":"norm"},"water_quality.UA.dsanpin-physiological":{"d":"zakon.rada.gov.ua","c":"","u":"https://zakon.rada.gov.ua/laws/show/z0452-10/print","k":"norm"},"water_treatment.EU.dwd2020-softened-minerals":{"d":"Directive (EU) 2020/2184 on the quality of water intended for human consumption (recast)","c":"Annex I, Part C, Notes; recital 17","u":"http://publications.europa.eu/resource/cellar/7e65c36f-44c0-11eb-b59f-01aa75ed71a1.0006.03/DOC_1","k":"recommendation"},"membrane.INT.filmtec-element-count-eq38":{"d":"DuPont FilmTec Reverse Osmosis Membranes Technical Manual, Form No. 45-D01504-en, Rev. 20, August 2026","c":"","u":"https://www.dupont.com/content/dam/water/amer/us/en/water/public/documents/en/RO-NF-FilmTec-Manual-45-D01504-en.pdf","k":"recommendation"},"brine.US.ct-ro-30gpd":{"d":"Connecticut DPH fact sheet «Reverse Osmosis Treatment of Private Drinking Water Supplies»","c":"reject water","u":"https://portal.ct.gov/-/media/Departments-and-Agencies/DPH/dph/environmental_health/pdf/21ReverseOsmosisTreatmentofPDWSpdf.pdf","k":"recommendation"},"brine.UA.regen-volumes-sellers":{"d":"ecosoft.ua","c":"","u":"https://ecosoft.ua/ua/filtr-umyagcheniya-vody-ecosoft-fu1054ci/","k":"practice"},"water_treatment.EU.en14743-salt-efficiency":{"d":"dvgw.de","c":"Salzverbrauch von Enthärtungsanlagen","u":"https://www.dvgw.de/medien/dvgw/leistungen/publikationen/twin-wasseraufbereitung-trinkwasserinstallation-maerz-2024.pdf","k":"norm"},"brine.UA.backwash-not-salty":{"d":"Formula Vody FFB 1665 Birm; Penn State Extension — Iron and Manganese in Private Water Systems","c":"","u":"https://formulavody.com.ua/uk/ffb-1665-birm-water-deferrization-system","k":"practice"},"water_quality.UA.dsanpin-well-20m":{"d":"zakon.rada.gov.ua","c":"","u":"https://zakon.rada.gov.ua/laws/show/z0452-10/print","k":"norm"},"brine.US.mn-50ft-well":{"d":"Minnesota Department of Health — Water Softeners (Noncommunity Public Water Supply Program fact sheet)","c":"Septic System Concerns; Dos and Don’ts","u":"https://www.health.state.mn.us/communities/environment/water/docs/factsheet/softeners.pdf","k":"norm"},"brine.PL.treatment-station-effluent-ground":{"d":"Rozporządzenie MGMiŻŚ z dnia 12 lipca 2019 r. w sprawie substancji szczególnie szkodliwych dla środowiska wodnego oraz warunków wprowadzania ścieków do wód lub do ziemi (Dz.U. 2019 poz. 1311)","c":"§ 11 ust. 1 pkt 1 lit. c, pkt 3; załącznik nr 4","u":"https://api.sejm.gov.pl/eli/acts/DU/2019/1311/text.html","k":"norm"},"brine.UA.dbn64-combined-if-cotreatable":{"d":"dreamdim.ua","c":"","u":"https://dreamdim.ua/wp-content/uploads/2019/10/DBN-V.2.5-64-2012-Vnutrishniy-vodoprovid-ta-kanali.pdf","k":"norm"},"brine.US.orenco-warranty":{"d":"Orenco CWP-SOFT-1 «Water Softeners and Wastewater Treatment Systems»","c":"—","u":"https://odl.orenco.com/documents/CWP-SOFT-1.pdf","k":"recommendation"},"membrane.INT.antiscalant-dose-vitec3000":{"d":"Avista (Kurita) Vitec™ 3000 Technical Data Sheet, REV 12.2023","c":"DOSING; INJECTING; DILUTION; «Certified to NSF/ANSI 60»","u":"https://www.hammarland.ax/system/files/media/document/Bilaga%209-3%2C%20TDS-Vitec-3000_AVT_EN_12-2023.pdf","k":"recommendation"},"membrane.INT.antiscalant-dosing-interlock":{"d":"DuPont FilmTec Reverse Osmosis Membranes Technical Manual, Form No. 45-D01504-en, Rev. 20 (August 2026)","c":"§3.14.3 Shut-down Switches, Table 30 «Provisions against undue operating conditions», p. 106","u":"https://www.dupont.com/content/dam/dupont/amer/us/en/water-solutions/public/documents/en/RO-NF-FilmTec-Manual-45-D01504-en.pdf","k":"recommendation"},"membrane.EU.antiscalant-dosing-pulse-meter":{"d":"sera (Seybert & Rahier GmbH), Proportional Dosing System PDS, brochure 76-05 en / 15.09.11","c":"Application; How the device works","u":"https://www.enviropro.co.uk/Docs/35997_1349434566886/preview/Proportional-Dosing-System-PDS.pdf","k":"recommendation"},"membrane.US.antiscalant-nsf60-maxuse":{"d":"info.nsf.org","c":"","u":"https://info.nsf.org/Certified/PwsChemicals/Listings.asp?TradeName=Vitec","k":"norm"},"cost.UA.cartridge-pp5-bb20":{"d":"prom.ua","c":"","u":"https://prom.ua/ua/p931720565-kartridzh-polipropilenovij-aquafilter.html","k":"price"},"membrane.INT.filmtec-capacity-peak-buffer-tank":{"d":"DuPont FilmTec Reverse Osmosis Membranes Technical Manual, Form No. 45-D01504-en, Rev. 20, August 2026","c":"","u":"https://www.dupont.com/content/dam/water/amer/us/en/water/public/documents/en/RO-NF-FilmTec-Manual-45-D01504-en.pdf","k":"recommendation"},"cost.UA.pumpstation-inverter-budget":{"d":"prom.ua","c":"","u":"https://prom.ua/ua/p2965935399-invertornaya-nasosnaya-stantsiya.html","k":"price"},"water_quality.UA.dsanpin-micro-wells":{"d":"zakon.rada.gov.ua","c":"","u":"https://zakon.rada.gov.ua/laws/show/z0452-10/print","k":"norm"},"membrane.UA.term-mineralnyi-sklad-zmishuvannia":{"d":"document.vobu.ua","c":"","u":"https://document.vobu.ua/wp-content/uploads/DBN/101.1.-DBN-V.2.5-742013.-Vodopostachannya.-Zovnishni-merezhi.pdf","k":"norm"},"membrane.UA.term-dominieralizatsiia-mineralizator":{"d":"repository.kpi.kharkov.ua","c":"","u":"https://repository.kpi.kharkov.ua/handle/KhPI-Press/72284","k":"recommendation"},"water_treatment.US.ro-pou-poe":{"d":"University of Nebraska–Lincoln Extension G1490 «Drinking Water Treatment: Reverse Osmosis» (rev. 2014)","c":"Treatment principles; Equipment","u":"https://extensionpubs.unl.edu/publication/g1490/2014/pdf/view/g1490-2014.pdf","k":"recommendation"},"water_treatment.US.unl-methods-matrix":{"d":"University of Nebraska–Lincoln Extension EC703 «Drinking Water Treatment: An Overview» (rev. 2014)","c":"Table I (problem → treatment); Table II (methods)","u":"https://extensionpubs.unl.edu/publication/ec703/2014/pdf/view/ec703-2014.pdf","k":"recommendation"},"water_quality.US.sm1030e-ion-balance":{"d":"ndep.nv.gov","c":"","u":"https://ndep.nv.gov/uploads/documents/2009-cation-anion-balance-guide.pdf","k":"recommendation"},"water_treatment.DE.din1988-mech-filter":{"d":"dvgw.de","c":"Mechanisch wirkende Filter","u":"https://www.dvgw.de/medien/dvgw/leistungen/publikationen/twin-wasseraufbereitung-trinkwasserinstallation-maerz-2024.pdf","k":"norm"},"water_treatment.US.h2s-by-level":{"d":"Penn State Extension — Hydrogen Sulfide (Rotten Egg Odor) in Water Wells","c":"Treatment options","u":"https://extension.psu.edu/hydrogen-sulfide-rotten-egg-odor-in-water-wells","k":"recommendation"},"water_treatment.UA.dbn74-mn-f-h2s":{"d":"document.vobu.ua","c":"","u":"https://document.vobu.ua/wp-content/uploads/DBN/101.1.-DBN-V.2.5-742013.-Vodopostachannya.-Zovnishni-merezhi.pdf","k":"norm"},"water_treatment.US.softener-no-tds":{"d":"Montana State University Extension Water Quality — Hardness fact sheet","c":"Treating Hard Water","u":"https://waterquality.montana.edu/well-ed/interpreting_results/fs_hardness.html","k":"recommendation"},"water_treatment.US.softener-high-tds":{"d":"WC&P International — C.F. «Chubb» Michaud, «Total Dissolved Solids Limits for Effective Softening» (01.02.2024)","c":"Sodium-to-Hardness Ratio; Figure 3","u":"https://wcponline.com/2024/02/01/total-dissolved-solids-limits-for-effective-softening/","k":"recommendation"},"water_treatment.US.chlorination-over-10":{"d":"Penn State Extension — Iron and Manganese in Private Water Systems","c":"Oxidation followed by filtration","u":"https://extension.psu.edu/iron-and-manganese-in-private-water-systems","k":"recommendation"},"water_treatment.US.catalytic-carbon-iron":{"d":"Penn State Extension — Iron and Manganese in Private Water Systems","c":"Other Options (aeration, catalytic carbon, polyphosphate)","u":"https://extension.psu.edu/iron-and-manganese-in-private-water-systems","k":"recommendation"},"water_treatment.US.birm-ph":{"d":"Penn State Extension — Iron and Manganese in Private Water Systems","c":"Oxidizing Filters (Birm)","u":"https://extension.psu.edu/iron-and-manganese-in-private-water-systems","k":"recommendation"},"water_treatment.UA.birm-feed-seller":{"d":"formulavody.com.ua","c":"","u":"https://formulavody.com.ua/uk/ffb-1665-birm-water-deferrization-system","k":"recommendation"},"water_treatment.US.birm-clack-mn-ph":{"d":"lenntech.com","c":"Conditions necessary for the use of Birm — Manganese Removal","u":"https://www.lenntech.com/Data-sheets/Clack-A8006-Birm-L.pdf","k":"recommendation"},"water_treatment.US.pyrolox-mno2":{"d":"Vibrantz (Prince) — Manganese Filter Media Brochure 2020 (Pyrolox Ore)","c":"Pyrolox Ore — Conditions for Operations","u":"https://vibrantz.com/wp-content/uploads/2022/12/103-Prince-Manganese-Filter-Media-Brochure-2020.pdf","k":"recommendation"},"water_treatment.US.greensand-3-10":{"d":"Penn State Extension — Iron and Manganese in Private Water Systems","c":"Oxidizing Filters","u":"https://extension.psu.edu/iron-and-manganese-in-private-water-systems","k":"recommendation"},"water_treatment.DE.din1988-softening-table":{"d":"dvgw.de","c":"Tabelle 1 «Wasseraufbereitung zur Verminderung von Steinbildung»","u":"https://www.dvgw.de/medien/dvgw/leistungen/publikationen/twin-wasseraufbereitung-trinkwasserinstallation-maerz-2024.pdf","k":"norm"},"water_treatment.US.nsf55-uv-classes":{"d":"wcponline.com","c":"Class A / Class B","u":"https://wcponline.com/2015/05/07/nsfansi-55-class-a-versus-class-b-uv-systems/","k":"norm"},"water_treatment.DE.magnetic-no-proof":{"d":"Bayerisches Landesamt für Umwelt, Merkblatt Nr. 1.6/5 «Alternative Wasserbehandlungsgeräte zur Verminderung der Steinbildung in Hausinstallationen» (Stand Juli 2010)","c":"1 Hintergrund; 4 Schlussfolgerungen","u":"https://www.lfu.bayern.de/wasser/merkblattsammlung/teil1_grundwasserwirtschaft/doc/nr_165.pdf","k":"recommendation"},"water_treatment.UK.dwi-uv":{"d":"Drinking Water Inspectorate — Private water supplies: treatment guide, UV disinfection","c":"UV disinfection","u":"https://www.dwi.gov.uk/private-water-supplies/pws-installations/treatment-guide-2/uv-disinfection/","k":"recommendation"},"membrane.INT.filmtec-tcf-formula":{"d":"DuPont FilmTec Reverse Osmosis Membranes Technical Manual, Form No. 45-D01504-en, Rev. 20, August 2026","c":"","u":"https://www.dupont.com/content/dam/water/amer/us/en/water/public/documents/en/RO-NF-FilmTec-Manual-45-D01504-en.pdf","k":"recommendation"},"membrane.INT.filmtec-osmotic-pressure-formula":{"d":"DuPont FilmTec Reverse Osmosis Membranes Technical Manual, Form No. 45-D01504-en, Rev. 20, August 2026","c":"","u":"https://www.dupont.com/content/dam/water/amer/us/en/water/public/documents/en/RO-NF-FilmTec-Manual-45-D01504-en.pdf","k":"recommendation"},"membrane.US.scale-nf-residential-recovery":{"d":"Peter S. Cartwright, «Nanofiltration—When It Works for the Whole House», Water Conditioning & Purification (WC&P), 13.11.2003","c":"","u":"https://wcponline.com/?p=17627","k":"practice"},"membrane.INT.filmtec-system-recovery-staging":{"d":"DuPont FilmTec Reverse Osmosis Membranes Technical Manual, Form No. 45-D01504-en, Rev. 20, August 2026","c":"","u":"https://www.dupont.com/content/dam/water/amer/us/en/water/public/documents/en/RO-NF-FilmTec-Manual-45-D01504-en.pdf","k":"recommendation"},"membrane.INT.scale-preventive-flush-small":{"d":"DuPont FilmTec Reverse Osmosis Membranes Technical Manual, Form No. 45-D01504-en, Rev. 20 (August 2026)","c":"§2.3.7 Preventive Cleaning, p. 34","u":"https://www.dupont.com/content/dam/dupont/amer/us/en/water-solutions/public/documents/en/RO-NF-FilmTec-Manual-45-D01504-en.pdf","k":"recommendation"},"membrane.INT.filmtec-midsize-well-flux":{"d":"dupont.com","c":"Table 1: Design guidelines for FilmTec elements in light industrial and small seawater applications","u":"https://www.dupont.com/content/dam/water/amer/us/en/water/public/documents/en/RO-NF-FilmTec-Membrane-Sys-Design-Guidelines-Midsize-Manual-Exc-45-D01588-en.pdf","k":"recommendation"},"membrane.INT.filmtec-4040-hydraulic-limits":{"d":"DuPont FilmTec Technical Manual Excerpt «Membrane System Design Guidelines for Midsize FilmTec Elements», Rev 11, February 2026","c":"","u":"https://www.dupont.com/content/dam/water/amer/us/en/water/public/documents/en/RO-NF-FilmTec-Membrane-Sys-Design-Guidelines-Midsize-Manual-Exc-45-D01588-en.pdf","k":"recommendation"},"membrane.INT.filmtec-single-module-recirculation":{"d":"DuPont FilmTec Reverse Osmosis Membranes Technical Manual, Form No. 45-D01504-en, Rev. 20, August 2026","c":"","u":"https://www.dupont.com/content/dam/water/amer/us/en/water/public/documents/en/RO-NF-FilmTec-Manual-45-D01504-en.pdf","k":"recommendation"},"membrane.INT.small-nf-ro-sec-kit-2026":{"d":"Boussouga Y.-A., Ladeia Ramos R., Ogunniyi E.O., Richards B.S., Schäfer A.I. «Energy efficiency of single-pass electrodialysis and nanofiltration/reverse osmosis for brackish water desalination: An experimental comparison», Desalination 621 (2026) 119670, doi:10.1016/j.desal.2025.119670 (CC BY)","c":"Abstract; §2.1","u":"https://publikationen.bibliothek.kit.edu/1000189470/172392515","k":"practice"},"cost.UA.electricity-household-2026":{"d":"zaxid.net","c":"","u":"https://zaxid.net/tsina_na_elektroenergiyu_z_1_zhovtnya_2026_shho_zminitsya_i_dlya_kogo_n1646578","k":"price"},"membrane.INT.life-element-small-systems":{"d":"DuPont FilmTec Reverse Osmosis Membranes Technical Manual, Form No. 45-D01504-en, Rev. 20 (August 2026)","c":"§3.9.2 Membrane System Design Guidelines for Midsize FilmTec Elements, Tables 23–24, p. 92","u":"https://www.dupont.com/content/dam/dupont/amer/us/en/water-solutions/public/documents/en/RO-NF-FilmTec-Manual-45-D01504-en.pdf","k":"recommendation"},"membrane.INT.filmtec-fouling-sdi-cleanings":{"d":"DuPont FilmTec Reverse Osmosis Membranes Technical Manual, Form No. 45-D01504-en, Rev. 20, August 2026","c":"","u":"https://www.dupont.com/content/dam/water/amer/us/en/water/public/documents/en/RO-NF-FilmTec-Manual-45-D01504-en.pdf","k":"recommendation"},"membrane.INT.cip-triggers":{"d":"DuPont FilmTec Reverse Osmosis Membranes Technical Manual, Form No. 45-D01504-en, Rev. 20 (August 2026)","c":"§6.3 Cleaning Requirements, p. 135","u":"https://www.dupont.com/content/dam/dupont/amer/us/en/water-solutions/public/documents/en/RO-NF-FilmTec-Manual-45-D01504-en.pdf","k":"recommendation"},"membrane.INT.cip-shutdown-flush":{"d":"DuPont FilmTec Reverse Osmosis Membranes Technical Manual, Form No. 45-D01504-en, Rev. 20 (August 2026)","c":"§5.4 RO and NF Systems Shut-down, p. 124–125","u":"https://www.dupont.com/content/dam/dupont/amer/us/en/water-solutions/public/documents/en/RO-NF-FilmTec-Manual-45-D01504-en.pdf","k":"recommendation"},"membrane.INT.filmtec-feed-bypass-blend":{"d":"DuPont FilmTec Reverse Osmosis Membranes Technical Manual, Form No. 45-D01504-en, Rev. 20, August 2026","c":"","u":"https://www.dupont.com/content/dam/water/amer/us/en/water/public/documents/en/RO-NF-FilmTec-Manual-45-D01504-en.pdf","k":"recommendation"},"membrane.US.calcite-clack-media":{"d":"clackcorp.com","c":"","u":"https://www.clackcorp.com/?p=728","k":"recommendation"},"membrane.INT.tool-dupont-wave-pro":{"d":"wateronline.com","c":"","u":"https://www.wateronline.com/doc/dupont-water-solutions-expands-data-driven-wave-pro-design-tool-with-reverse-osmosis-and-nanofiltration-0001","k":"practice"},"membrane.INT.tool-hydranautics-imsdesign":{"d":"Hydranautics / Nitto — IMSDesign Cloud (+ RODataXL)","c":"","u":"https://membranes.com/solutions/software/","k":"practice"},"cost.UA.uv-lamp-e720":{"d":"prom.ua","c":"","u":"https://prom.ua/ua/p2496282956-smennyj-izluchatel-dlya.html","k":"price"},"cost.UA.antiscalant-vitek3000-1l":{"d":"prom.ua","c":"","u":"https://prom.ua/ua/p938393176-antiskalant-vitek-3000.html","k":"price"},"cost.UA.antiscalant-ecotec-ro3010-10kg":{"d":"akvo.com.ua","c":"","u":"https://akvo.com.ua/ua/2473-ecosoft-ecotec-ro-3010-antiskalant-dispergent-10-kg","k":"price"},"membrane.INT.cip-chemistry":{"d":"DuPont FilmTec Reverse Osmosis Membranes Technical Manual, Form No. 45-D01504-en, Rev. 20 (August 2026)","c":"§6.2 Table 35; §6.7; §6.8 Table 37; §6.9.2–6.9.3 Tables 38–39, pp. 135–141","u":"https://www.dupont.com/content/dam/dupont/amer/us/en/water-solutions/public/documents/en/RO-NF-FilmTec-Manual-45-D01504-en.pdf","k":"recommendation"},"water_treatment.UA.user-citric-wash-max-temp":{"d":"source","c":"","u":"","k":"practice"},"water_treatment.UA.user-cartridge-5um-interval":{"d":"source","c":"","u":"","k":"practice"},"cost.UA.membrane-ro2540-vontron-ulp21":{"d":"prom.ua","c":"","u":"https://prom.ua/p261485613-membrana-obratnogo-osmosa.html","k":"price"},"cost.UA.membrane-bw4040-vontron-ulp21-waterstar":{"d":"waterstar.in.ua","c":"","u":"https://waterstar.in.ua/ua/p1509665437-membrana-vontron-tiporazmer.html","k":"price"},"cost.UA.membrane-nf4040-csm-ne4040-90":{"d":"aquaforesight.com.ua","c":"","u":"https://aquaforesight.com.ua/ua/p1124894508-membrana-csm-ne4040.html","k":"price"},"cost.UA.membrane-nf4040-keensen-nf1":{"d":"prom.ua","c":"","u":"https://prom.ua/ua/p2224543171-membrana-nanofiltratsii-keensen.html","k":"price"},"cost.UA.membrane-bw4040-filmtec-xle":{"d":"prom.ua","c":"","u":"https://prom.ua/p3164328383-membrannyj-element-ecosoft.html","k":"price"},"cost.UA.ro-system-250lh-ulpro-nomembrane":{"d":"prom.ua","c":"","u":"https://prom.ua/ua/p2663551824-promyshlennyj-obratnyj-osmos.html","k":"price"},"cost.UA.ro-system-250lh-pvro":{"d":"prom.ua","c":"","u":"https://prom.ua/ua/p938393249-sistema-zvorotnogo-osmosu.html","k":"price"},"cost.UA.ro-controller-roc2315":{"d":"prom.ua","c":"","u":"https://prom.ua/ua/p16215352-kontroller-dlya-sistem.html","k":"price"},"cost.UA.ro-dosing-station-ecosoft-prop":{"d":"akvo.com.ua","c":"","u":"https://akvo.com.ua/ua/3725-ecosoft-stantsiya-proportsionalnogo-dozirovaniya-proizvoditelnostyu-01---7-lchas-60-l-d03656025","k":"price"},"cost.UA.housing-bb20":{"d":"prom.ua","c":"","u":"https://prom.ua/ua/p2229321622-korpus-filtra-kaplya.html","k":"price"},"cost.UA.tank-500l-food-3layer":{"d":"prom.ua","c":"","u":"https://prom.ua/ua/p1904321913-emkost-trehslojnaya-pischevaya.html","k":"price"},"cost.UA.tank-1000l-food-vert-3layer":{"d":"prom.ua","c":"","u":"https://prom.ua/p2571423330-emkost-1000l-pisch.html","k":"price"},"cost.UA.tank-1000l-food-vert-europlast":{"d":"prom.ua","c":"","u":"https://prom.ua/ua/p3150425428-emkost-dlya-vody.html","k":"price"},"cost.UA.tank-float-switch":{"d":"prom.ua","c":"","u":"https://prom.ua/ua/p3084347533-poplavkovyj-vyklyuchatel-urovnya.html","k":"price"},"cost.UA.pumpstation-inverter-scala2":{"d":"prom.ua","c":"","u":"https://prom.ua/ua/p1291322581-nasosnaya-ustanovka-new.html","k":"price"},"cost.UA.membrane-cleaning-service-waters":{"d":"waters.com.ua","c":"","u":"https://waters.com.ua/promyvannya-membran-zvorotnogo-osmosu/","k":"price"},"cost.UA.membrane-cleaning-service-iwater":{"d":"iwater.kiev.ua","c":"","u":"https://iwater.kiev.ua/ua/p823939010-himicheskaya-promyvka-membrany.html","k":"price"},"cost.UA.calcite-clack-15l-vencon":{"d":"vencon.ua","c":"","u":"https://vencon.ua/ua/products/zasypka-ecosoft-calcite-15-kg","k":"price"},"water_quality.UA.dsanpin-fe-mn":{"d":"zakon.rada.gov.ua","c":"","u":"https://zakon.rada.gov.ua/laws/show/z0452-10/print","k":"norm"},"water_quality.US.private-wells-unregulated":{"d":"US EPA — Private Drinking Water Wells (landing page)","c":"","u":"https://www.epa.gov/privatewells","k":"norm"},"water_quality.US.cfr143-secondary":{"d":"40 CFR 143.3 Secondary maximum contaminant levels (National Secondary Drinking Water Regulations)","c":"§ 143.3","u":"https://www.law.cornell.edu/cfr/text/40/143.3","k":"recommendation"},"water_quality.US.cfr141-nitrate":{"d":"40 CFR 141.62 Maximum contaminant levels (MCLs) for inorganic contaminants (National Primary Drinking Water Regulations)","c":"(b)(7)–(9)","u":"https://www.law.cornell.edu/cfr/text/40/141.62","k":"norm"},"water_quality.US.cfr141-coliform":{"d":"40 CFR 141.63 Maximum contaminant levels (MCLs) for microbiological contaminants (National Primary Drinking Water Regulations; Revised Total Coliform Rule)","c":"(c)","u":"https://www.law.cornell.edu/cfr/text/40/141.63","k":"norm"},"cost.US.softener-toh-2026":{"d":"thisoldhouse.com","c":"","u":"https://www.thisoldhouse.com/plumbing/water-softener-system-cost","k":"price"},"cost.US.ro-toh-2026":{"d":"This Old House — How Much Does a Reverse Osmosis System Cost in 2026?","c":"System type; Maintenance; DIY vs. Professional","u":"https://www.thisoldhouse.com/plumbing/reverse-osmosis-system-cost","k":"price"},"water_quality.UK.pws-eng-national-iron-mn-na":{"d":"The Private Water Supplies (England) Regulations 2016 (SI 2016/618)","c":"Schedule 1, Part 1, Table B, Part II (national requirements)","u":"https://www.legislation.gov.uk/uksi/2016/618/schedule/1","k":"norm"},"water_quality.UK.pws-eng-indicators":{"d":"The Private Water Supplies (England) Regulations 2016 (SI 2016/618)","c":"Schedule 1, Part 2, Table C (indicator parameters)","u":"https://www.legislation.gov.uk/uksi/2016/618/schedule/1","k":"norm"},"water_quality.UK.pws-eng-micro-chem-health":{"d":"The Private Water Supplies (England) Regulations 2016 (SI 2016/618)","c":"Schedule 1, Part 1, Tables A–B; reg. 4(c); Table D","u":"https://www.legislation.gov.uk/uksi/2016/618/schedule/1","k":"norm"},"water_quality.UK.no-hardness-standard":{"d":"Drinking Water Inspectorate — Private water supplies treatment guide: The physical and chemical properties of water","c":"Hardness, Table 1","u":"https://www.dwi.gov.uk/private-water-supplies/pws-installations/treatment-guide-2/the-physical-and-chemical-properties-of-water/","k":"recommendation"},"cost.UK.softener-install-2026":{"d":"MyJobQuote — Water Softener Installation Cost Guide (2026)","c":"Average cost; Annual servicing; Maintenance","u":"https://www.myjobquote.co.uk/costs/water-softener-installation","k":"price"},"cost.UK.ro-undersink":{"d":"UK Water Filters — Under-sink reverse osmosis water filter system","c":"","u":"https://www.uk-water-filters.co.uk/products/water_filters_reverse_osmosis","k":"price"},"cost.UK.uv-aquacure":{"d":"Aquacure — Stainless steel UV steriliser systems (WRAS approved AC UV)","c":"","u":"https://www.aquacure.co.uk/uv-water-treatment-systems/uv-steriliser-sytems","k":"price"}},"market":"US","markets":["UA","US","UK"],"units":{"UA":{},"US":{"hard":"gpg"},"UK":{"hard":"caco3","tds":"uS/cm","fe":"ug/l","mn":"ug/l"}},"slugs":{"water":"well-water-treatment-calculator-us","membrane":"whole-house-reverse-osmosis-calculator-us"},"params":[{"k":"tds","unit":"mg/l","units":["mg/l","uS/cm"]},{"k":"hard","unit":"meq","units":["meq","mmol_eu","dH","fH","caco3","gpg"]},{"k":"ca","unit":"mg/l"},{"k":"mg","unit":"mg/l"},{"k":"na","unit":"mg/l"},{"k":"k","unit":"mg/l"},{"k":"cl","unit":"mg/l"},{"k":"so4","unit":"mg/l"},{"k":"hco3","unit":"mg/l","units":["mg/l","meq"]},{"k":"fe","unit":"mg/l","units":["mg/l","ug/l"]},{"k":"mn","unit":"mg/l","units":["mg/l","ug/l"]},{"k":"ox","unit":"mg/l"},{"k":"no3","unit":"mg/l"},{"k":"h2s","unit":"mg/l"},{"k":"ph","unit":""},{"k":"turb","unit":"ntu"},{"k":"cl2","unit":"mg/l"},{"k":"coli","unit":"cfu"},{"k":"ecoli","unit":"cfu"},{"k":"sio2","unit":"mg/l","units":["mg/l","si"]},{"k":"ba","unit":"mg/l","units":["mg/l","ug/l"]},{"k":"sr","unit":"mg/l","units":["mg/l","ug/l"]},{"k":"f","unit":"mg/l"}],"required":["tds","hard","fe","mn","na","cl","so4","ox"],"limits":{"physio":{"min":{"tds":200,"hard":1.5,"alk":0.5,"ca":25,"mg":10,"na":2,"k":2},"max":{"tds":500,"hard":7,"alk":6.5,"ca":75,"mg":50,"na":20,"k":20}},"anses":{"hard":1.6,"alk":1.6}},"defaults":{"source":"well","persons":4,"hotOver60":false},"wizard":{"map":{},"limits":{"bedrooms":[1,6],"baths":[1,4],"area":[40,400],"fp":[3,60]}},"result":null}}
